HOME UPS 1100VA

 

 

SlNo TESTING PARAMETERS SPECIFICATIONS
A BATTERY MODE 1100VA/12V
A.1 No Load Current @ Switch OFF 180 mA
A.2 Battery Voltage @ No LOAD 12V
A.3 Output Voltage @ No LOAD 225 ± 7V
A.4 Output Frequency @ No LOAD 50 ± 1Hz
A.5 Output Frequency @ Full LOAD 50 ± 1Hz
A.6 Battery Current @ Full LOAD 65 ± 1 Amp.
A.7 Fan Run  @ Very First Start Up Fan Operates Properly
A.8 Short Circuit > 300%
A.9 Crest Factor 300%
A.10 Harmonic distortion in O/P wavefrom(linear load 3%
B UPS MODE
B.1 Low Cut With Phase Match 180 ± 5V
B.2 Low Cut Recovery With Phase Match 9-12V Hysterisis from  > Low Cut Voltage
B.3 High Cut With Phase Match 270 ± 5V
B.4 High Cut Reovery With Phase Match 9-12V Hysterisis from < High Cut Voltage
B.5 Change Over Time From Mains To UPS 10msec
B.6 Change Over Time From UPS To Mains 8msec
C NORMAL MODE
C.1 Low Cut With Phase Match 90 ± 5V
C.2 Low Cut Recovery With Phase Match 9-12V Hysterisis > Low Cut Voltage
C.3 High Cut With Phase Match 290 ± 5V
C.4 High Cut Reovery With Phase Match 9-12V Hysterisis < High Cut Voltage
C.5 Change Over Time From Mains To UPS 20msec
C.6 Change Over Time From UPS To Mains 10msec
C.7 Mains Tap Cut Voltage 180 ± 5V
SlNo TESTING PARAMETERS SPECIFICATIONS
D CHARGING MODE 1100VA/12V
D.1 Low Charging Current @ 220V AC (NC) 13.5 ± 1.0A
D.2 High Charging Current @ 220V AC (HC) 18.0 ± 1.0A
D.3 Boost Charging Voltage (HC/NC) 14.4 ± 0.2V
D.4 Float Charging Voltage (HC/NC) 13.7 ± 0.2V

 